ST – RCT1000 – Coriolis Flow Meter

SUR-TECH CORIOLIS FLOW METER

SUR-TECH CORIOLIS RCT1000 FLOW
METER

The ST RCT1000 Coriolis mass flow meter identifies flow rate by directly measuring mass flow and density of fluids over a wide range of process temperatures with a high degree of accuracy. For homogenous fluids consisting of two components like sugar and water, the ST RCT1000 Coriolis system can derive the concentration and mass of each component based on fluid properties and density measurement. Furthermore, the unobstructed, open flow design makes it suitable for a variety of fluids such as slurries and other viscous, nonconductive fluids that are difficult to measure with other technologies.

Features

  • Highly accurate direct measurement of: Mass Flow / Density
  • Derive concentration of homogenous liquids
  • No straight-run requirements and low maintenance operation
  • Advanced fluid diagnostic software
  • Open flow path and flexible integration options

Certifications

  • ATEX / IECEx
    – Integral mount II 2 G Ex db ia IIB T4 Gb
    – Remote transmitter II 2 (1) G Ex db [ia Ga] IIB T6…T3 Gb
    – Remote sensor II 1 G Ex ia IIB T6…T3 Ga
  • cCSAus
    – CI I, Zn 1 AEx/Ex db ia IIB T4 Gb Explosion-proof for CI I Div 1 Grp CD with Intrinsically Safe Sensor for CI I Div 1 Grp CD
    – CI I, Zn 1 AEx/Ex db [ia Ga] IIB T6…T3 Gb Explosion-proof for CI I Div 1
    – Grp CD

Operation

As fluid flows through the vibrating sensor tube, forces induced by the flow cause the tube to twist slightly. These small deflections are measured by carefully placed detectors. A phase shift occurs between detector signals that is directly proportional to mass flow rate. As the fluid density varies, the resonant frequency at which the tube vibrates changes, which is also measured by the detectors. These larger sensors have two tubes that are vibrated in opposing directions in order to reduce the effect of process vibration on the flow measurement. Temperature is measured by an internal RTD in order to calculate thermal effects on the tube vibrating frequency.

SPECIFICATIONS
Size0.5” – 24” (other sizes available upon request)
ConnectionsFlanged 150, 300 ; NPT ; DN PN40 ; Tri-Clamp
Enclosure OptionsNEMA 4 (IP65), NEMA 4X (IP66)
Power RequirementsModel RCTN: 115/230V AC; ±15% 50/60 Hz 25W maximum or 20…28V DC; 15W maximum
Model RCTX: 18…28V DC; 15W maximum
Analog I/O OutputsModel RCTN: Three 4…20 mA (0…22 mA capable), maximum load 500 Ohms,
approximately 16 bit resolution outputs; assignable to mass flow, volume, density,
temperature, concentration, PID and similar measurements. User defined fault condition
output value anywhere in the 0…22 mA range

Model RCTX: Two (three with HART Option) 4…20 mA (0…22 mA capable), maximum
load 500 Ohms, approximately 16 bit resolution outputs; assignable to mass flow, volume,
density, temperature, concentration, PID and similar measurements. User defined fault
condition output value anywhere in the 0…22 mA range